Troubleshooting a Data Link Layer Problem
308656-14.00 Rev 00
5-15
wfFDDIRingOverrunRx (get wfFddiEntry.21.*)
This shows the number of logical link control (LLC) reception ring
overrun events. These errors are equivalent to lack-of-resource errors on a
synchronous or Ethernet port. Each error indicates one lost packet.
Troubleshoot a problem with reception ring overruns as follows:
-- Enter the following command to verify how many buffers are
currently free in the slot:
get wfKernelEntry.*.
<slot>
-- Go to “Memory or Buffer Problem” in Chapter 3 if you need an
explanation of the memory issues.
-- Increase the size of the reception queue by setting the wfFddiEntry.43
attribute (wfFDDICfgRxQueueLength). The maximum setting is 255.
wfFDDITxClipFrames (
get wfFddiEntry.40.*)
This shows the number of dropped (clipped) frames that the router could
not add to the driver’s transmission routine because of transmission
congestion. Determine what type of data is overrunning the transmission
port by using a network analyzer or the Packet Capture utility.
Enter the following command to verify how many buffers are currently
free in the slot:
get wfKernelEntry.*.
<slot>
Go to “Memory or Buffer Problem” in Chapter 3 for an explanation of the
memory issues.
Increase the size of the transmission queue by setting the wfFddiEntry.42
attribute (wfFDDICfgTxQueueLength). The maximum setting is 255.
3.
Enter the Technician Interface command
get wfFddiSmtEntry.9.*
or use
the Quick Get path
wfLine > wfFddiGroup > wfFddiSmtGroup >
wfFddiSmtTable > wfFddiSmtCfState
.
This shows the connection of the station to the ring. The codes are as follows:
1 = isolated
•2=wrap S
•3=wrap A
•4=wrap B