Troubleshooting a Data Link Layer Problem
308656-14.00 Rev 00
5-29
If token ring Debug Event 36 (Connector MAU<SlotConnector> Ring Status
Change<
4_digit_hex_code>
) appears, convert the 4-digit number from
hexadecimal to binary. Assign the position numbers 0 through 10 to the first
11 digits, from left to right.
Look for the position number of the 1 bit in the following list:
• 0 indicates signal loss.
• 1 indicates a hardware error.
• 2 indicates a software error.
• 3 indicates a transmitter beacon.
• 4 indicates a lobe wire fault.
• 5 indicates an automatic removal error.
• 6 is reserved for future use.
• 7 indicates a remove received.
• 8 indicates a counter overflow.
• 9 indicates a single station.
• 10 indicates a ring recovery.
2.
If you are using the Technician Interface, enter the following command to
list the instances of the wfTokenRingEntry object:
list instances wfTokenRingEntry
3.
If you are using the Technician Interface, enter the following command to
display the values of the wfTokenRingEntry object for the instance in
question:
get wfTokenRingEntry.*.
<instance>
Or, use the Quick Get path wfLine > wfTokenRingTable.