Using the Technician Interface to Configure and Run Packet Capture
308656-14.00 Rev 00
B-43
Parameter: Line Number
Attribute Name: wfPktCaptureLineNumber
Attribute Number: 7
Default: Set by Packet Capture code
Options: Based on the encoded value
Function: Uniquely identifies a circuit.
MIB Object ID: 1.3.6.1.4.1.18.3.4.21.1.1.7
Parameter: Buffer Size
Attribute Name: wfPktCaptureBufSize
Attribute Number: 8
Default: None
Options: 1 (allocates 1024 bytes)
|
2 (allocates 2048 bytes)
|
Up to the available
contiguous memory divided by 1024
Function: Sets the size of the file stored in buffer memory, in 1024-byte increments.
The upper limit is the maximum number of contiguous bytes of memory
available on the slot. You can determine the maximum number of
contiguous bytes by entering the following command:
get wfKernelEntry.6.
<slot no.>
6
represents the wfKernelMemoryMaxSegFree attribute.
Instructions: If the allocation of the buffer leaves less than 200 KB of memory, a
warning appears in the log. The operating system may need to allocate
and free memory. If the memory needed is not available, an error occurs.
If errors occur after you start Packet Capture, stop it and allocate a smaller
buffer size.
MIB Object ID: 1.3.6.1.4.1.18.3.4.21.1.1.8