Reading the Event Log
308656-14.00 Rev 00
A-29
MCT1 Log Information in a Lab Environment
The log messages in this section show what happens when you access the MCT1
Line Tests option. In the sample display, port 2 of an MCT1-2 installed in slot 5 is
sending a payload loopback to port 1 of an MCT1-2 in slot 4. See Configuring
WAN Line Services for information about testing MCT1 lines.
When you enter the Technician Interface script command
show ds1e1 port
, the
Technician Interface displays the MCT1-2 port setup, as follows:
[3:1]$ show ds1e1 port
DS1E1 Port Status:
------------------
2 entries in table.
When the remote slot (slot 4) receives a loop-up or loop-down command, the
remote yellow loopback LED lights on port 1 in slot 4, and the following
messages appear in the log:
# 2: mm/dd/yy 08:56:17.563 INFO SLOT 4 DS1E1 Code: 55
Connector COM2 received loop-up code
# 18: mm/dd/yy 09:08:47.872 INFO SLOT 4 DS1E1 Code: 56
Connector COM2 received loop-down code
# 3: mm/dd/yy 10:31:12.638 INFO SLOT 2 MIB Code: 5
wfDs1E1ActionEntry.5.905102 set to 5
# 4: mm/dd/yy 10:31:12.683 INFO SLOT 4 DS1E1 Code: 30
Connector COM1 Unscheduled FDL message - Payload Loopback Activate.
# 5: mm/dd/yy 10:31:12.687 INFO SLOT 4 DS1E1 Code: 22
Connector COM1, Logical Line 1 LLC service withdrawn.
# 6: mm/dd/yy 10:31:33.105 WARNING SLOT 5 DS1E1 Code: 4
Connector COM2, Logical Line 1 receiver timeout.
# 7: mm/dd/yy 10:31:33.109 DEBUG SLOT 5 DP Code: 23
dp_line_map - Line GH 0x8400b4e3 died, cct 3
# 8: mm/dd/yy 10:31:33.113 INFO SLOT 5 DS1E1 Code: 22
Connector COM2, Logical Line 1 LLC service withdrawn.
# 9: mm/dd/yy 10:31:33.113 DEBUG SLOT 5 DP Code: 41
LINE_DOWN msg rcvd for line gate 0x400b4e3 on cct 3.
Found dead line 0x400b4e3 at offset 0
Slot Conn State MTU Loopback
State
Accept
Loopback
BERT
Mode
Line
Type
Line
Coding
FDL
Type
FDL
Addr
4 1 Loopback 1600 Net
Payload
Enabled Off ESF B8ZS ANSI BY
5 2 Up 1600 No Loop Enabled Off ESF B8ZS ANSI BY
Komentarze do niniejszej Instrukcji