Avaya Troubleshooting Routers Instrukcja Naprawy Strona 219

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 218
Using the Technician Interface to Configure and Run Packet Capture
308656-14.00 Rev 00
B-25
Specifying the Offset
Enter the following Technician Interface command to specify the number of bytes
after the Reference with which to begin the comparison:
set wfPktCaptureEntry.
<attribute_no.>
.
<line_no.> <value>
;commit
<attribute_no.>
is one of the following:
15 for Receive Filter 1
Represents the wfPktCaptureRxFltr1Offset attribute
25 for Receive Filter 2
Represents the wfPktCaptureRxFltr2Offset attribute
20 for Transmit Filter 1
Represents the wfPktCaptureTxFltr1Offset attribute
31 for Transmit Filter 2
Represents the wfPktCaptureTxFltr2Offset attribute
<line_no.>
is the number displayed after you issued the get command in “Creating
an Instance of Packet Capture.” To list the current line numbers associated with
Packet Capture, enter the command
list instances wfPktCaptureEntry
.
<value>
is any number up to the number of bytes in the packet. For detailed
instructions, refer to the media you are filtering in “Media-Specific Instructions
and Examples” on page B-51.
Specifying the Number of Bytes
Enter the following Technician Interface command to specify the number of bytes
to compare with the string:
set wfPktCaptureEntry.
<attribute_no.>
.
<line_no.>
<value>
;commit
<attribute_no.>
is one of the following:
17 for Receive Filter 1
Represents the wfPktCaptureRxFltr1Size attribute
27 for Receive Filter 2
Represents the wfPktCaptureRxFltr2Size attribute
Przeglądanie stron 218
1 2 ... 214 215 216 217 218 219 220 221 222 223 224 ... 267 268

Komentarze do niniejszej Instrukcji