# 94: mm/dd/yy 13:13:51.552 INFO SLOT 2 SYNC Code: 13
Connector COM1 LLC1 service withdrawn.
The following message is normal after a dial-on-demand connection terminates:
# 95: mm/dd/yy 13:13:51.556 DEBUG SLOT 2 SWSERV Code: 46
Demand line failed for circuit 2.
sw_dd_line_fail set in use circuit to zero for com 1.
The router completes the orderly termination of the dial-on-demand link by
re-initializing the port.
# 96: mm/dd/yy 13:13:51.572 INFO SLOT 2 SYNC Code: 9
Connector COM1 enabled.
# 97: mm/dd/yy 13:13:51.841 DEBUG SLOT 2 SYNC Code: 16
Connector COM1 initialization complete
Environment address - 3051ea30 Line record address -
3052e03c
Hardware map address - 30526e3c Initialization block -
80007c00
Receive descriptor ring - 80006000 Transmit descriptor ring -
80006800
# 98: mm/dd/yy 13:13:51.841 DEBUG SLOT 2 PCAP Code: 67
interface became local - line 202101
intf gate spawned - line 202101
# 99: mm/dd/yy 13:13:51.849 DEBUG SLOT 2 PCAP Code: 65
wait_state - line 202101
# 100: mm/dd/yy 13:13:52.846 DEBUG SLOT 2 SWSERV Code: 46
Connector COM1: FSM State: V25BIS_DISCONNECTED(0)
Connector COM1: FSM Event: V25BIS_EVENT_CCT_UP(1); isdn flags: 0x0
# 101: mm/dd/yy 13:13:52.846 INFO SLOT 2 MODEMIF Code: 22
Connector COM1: enable requested on cct 65535
# 102: mm/dd/yy 13:13:53.406 DEBUG SLOT 2 SWSERV Code: 46
Connector COM1: FSM State: V25BIS_WAIT_FOR_CTS(1)
Connector COM1: FSM Event: V25BIS_EVENT_CTS_UP(5); isdn flags: 0x1
# 103: mm/dd/yy 13:13:53.406 TRACE SLOT 2 MODEMIF Code: 53
Connector COM1: CTS has come up.
# 104: mm/dd/yy 13:13:53.406 DEBUG SLOT 2 MODEMIF Code: 9
Connector COM1: modem present V.25bis mode
# 105: mm/dd/yy 13:13:53.406 DEBUG SLOT 2 SWSERV Code: 46
Line Mgr received line ready for line 1
# 106: mm/dd/yy 13:13:53.406 INFO SLOT 2 SWSERV Code: 10
Sync Line 1 available for dial on demand pool 1.
# 107: mm/dd/yy 13:13:53.406 INFO SLOT 2 SYNC Code: 11
Connector COM1 providing LLC1 service.