Troubleshooting Routers
3-18
308656-14.00 Rev 00
Go to the appropriate section to determine which slot sent the backplane BofL
packet:
If the number 0x0f00bbbb is in the same location of your display as it is in
Figure 3-2
, go to “Finding the Slot That Sent a Bad Backplane BofL Packet
If the number 0x0f00bbbb is not in the same location, go to “Finding the Slot
That Sent a Bad Packet That Was Not a BofL Packet
Finding the Slot That Sent a Bad Backplane BofL Packet
Determine which slot sent the BofL packet that failed as follows:
1.
Find the number 0x0f00bbbb.
2.
Find the number to the right of the number 0x0f00bbbb.
In Figure 3-2
, this number is 0x0004000A.
3.
Convert the last four digits of that number to decimal.
In the following example, slot 10 sent the bad backplane BofL packet:
0x000A = 10
4.
Call the Nortel Networks Technical Solutions Center and describe the
problem.
Depending on whether the slot sending or receiving the packet is always the
same, you may need to replace the processor.