Reading the Event Log
308656-14.00 Rev 00
A-23
Dial-on-Demand V.25bis
The following log shows a successful dial-on-demand connection between the
COM1 port in slot 2 and a modem configured for V.25bis.
These messages appear only when you click on the port configured for
dial-on-demand, and set the Debug option under the Modem definition to
Enabled. If you are using the Technician Interface, set attribute #29 (the debug
attribute) of the object wfModemIfEntry to 1 (1 = enabled, 2 = disabled). The
Debug option is available with router software Version 8.01 and later.
The following message indicates that the Sync software module enabled the
COM1 port:
# 9: mm/dd/yy 13:07:24.725 INFO SLOT 2 SYNC Code: 9
Connector COM1 enabled.
The port completes initialization.
# 10: mm/dd/yy 13:07:24.995 DEBUG SLOT 2 SYNC Code: 16
Connector COM1 initialization complete
Environment address - 3051ea30 Line record address -
3052e03c
Hardware map address - 30526e3c Initialization block -
80007c00
Receive descriptor ring - 80006000 Transmit descriptor ring -
80006800
# 11: mm/dd/yy 13:07:24.995 DEBUG SLOT 2 PCAP Code: 67
interface became local - line 202101
intf gate spawned - line 202101
# 12: mm/dd/yy 13:07:25.002 DEBUG SLOT 2 PCAP Code: 65
wait_state - line 202101
The FSM messages indicate that the modem and the router are communicating.
The first FSM message shows the state the router was in when the FSM Event that
follows occurred.
# 13: mm/dd/yy 13:07:26.031 DEBUG SLOT 2 SWSERV Code: 46
Connector COM1: FSM State: V25BIS_DISCONNECTED(0)
Connector COM1: FSM Event: V25BIS_EVENT_CCT_UP(1); isdn flags: 0x0