Configuring IP Utilities
3-2 117358-A Rev. A
Using the BCC
By default, the router sets the minimum retransmission timeout value to 250
milliseconds (ms).
To specify a value for the minimum retransmission timeout, navigate to the TCP
prompt and enter:
min-rto
integer
integer
is a value from 100 to 15000 ms (msec.)
For example, the following command sets the value for the minimum
retransmission timeout to 300 ms:
tcp# min-rto 300
tcp#
Using Site Manager
Complete the tasks in the following table to specify a value for the minimum
retransmission timeout.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose Protocols.
The Protocols menu opens.
2. Choose Global Protocols. The Global Protocols menu opens.
3. Choose TCP. The TCP menu opens.
4. Choose Global. The Edit TCP Global Parameters window
opens.
5. Set the Min. Retransmission Timeout
(msec.) parameter. Click on Help or see
the parameter description on page A-2.
6. Click on OK. Site Manager saves your changes and
exits the window.