Configuring IP Utilities
A-2 117358-A Rev. A
TCP Global Parameters
Use the following guidelines to configure TCP global parameters in the
Configuration Manager window.
Parameter: Enable/Disable
Path: Protocols > Global Protocols > TCP > Global
Default: Enable
Options: Enable | Disable
Function: Enables or disables TCP on the router.
Instructions: Select Disable to disconnect from TCP. Also, you can select Disable if you do
not need TCP, but want to access previous TCP statistics.
MIB Object ID 1.3.6.1.4.1.18.3.5.3.3.1.2
Parameter: Min. Retransmission Timeout (msec.)
Path: Protocols > Global Protocols > TCP > Global
Default: 250
Options: 100 through 15000 ms
Function: Sets the minimum value for the retransmission timeout. When one side of a TCP
connection sends a frame and does not receive an acknowledgment from the
other side of the connection within the timeout period, the sending station
retransmits the frame.
Instructions: Specify the value you want to use for the minimum timeout period. If you are
transmitting on a high-speed network and you set the parameter value too high,
network performance may degrade, because TCP must wait for the timeout
period to elapse before retransmitting unacknowledged data.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.3.1.5