Parameter Descriptions
117358-A Rev. A A-11
Parameter: TI More
Path: Protocols > Global Protocols > Telnet Server > Global
Default: Enable
Options: Enable
| Disable
Function: Specifies whether the Technician Interface pauses after each screen fills with
data.
Instructions: Select Enable to configure the Technician Interface to pause after each screen
lls with data. Select Disable to configure the Technician Interface not to pause
after each screen fills with data.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.7.1.4
Parameter: TI Prompt
Path: Protocols > Global Protocols > Telnet Server > Global
Default: None
Options: 1 to 18 alphanumeric characters
Function: Specifies the character string used as the login prompt on the Telnet Technician
Interface console screen.
Instructions: Specify a character string.
Site Manager disconnects the current session if you modify the TI Prompt
parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.7.1.5
Parameter: Login Timeout (min.)
Path: Protocols > Global Protocols > Telnet Server > Global
Default: 1
Options: 1 to 99 minutes (99 = infinity)
Function: Specifies the number of minutes that can elapse before the Technician Interface
disconnects the Telnet session if you do not enter a login ID at the login prompt.
Instructions: Accept the default value (1 minute) or specify a different value.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.7.1.6