Monitoring ATM Using the BCC show Command
117374-C Rev 00
B-31
Line Stats
Slot/<Module>/Conn The slot, module, and connector number of the SONET circuit.
Circuit Name of the circuit associated with this line.
Interval A historical breakdown of intervals, including:
• The current interval (incomplete)
• All but the last two intervals (that is, all intervals except the
current interval and the previous interval)
• The previous interval (that is, the last complete interval)
• All of the intervals (total)
LESs The number of line errored seconds (LESs) for each interval
category.
SEFSs The number of severely errored framing seconds (SEFSs) for each
interval category.
UASs The number of unavailable seconds (UASs) for each interval
category.
LCVs The number of line coding violations (LCVs) for each interval
category.
Pbit Status
Slot/<Module>/Conn The slot, module, and connector number of the SONET circuit.
Circuit Name of the circuit associated with this line.
Interval A historical breakdown of intervals, including:
• The current interval (incomplete)
• All but the last two intervals (that is, all intervals except the
current interval and the previous interval)
• The previous interval (that is, the last complete interval)
• All of the intervals (total)
PESs The number of P-bit errored seconds (PESs) for each interval
category.
PSESs The number of P-bit severely errored seconds (PSESs) for each
interval category.
UASs The number of unavailable seconds (UASs) for each interval
category.
PCVs The number of P-bit coding violations (PCVs) for each interval
category.