Configuring ATM and MPLS Services
5-36
117374-C Rev 00
Changing VPI Numbers
By default, the VPI for both the signaling and ILMI control VC is 0. However,
you can change the VPI number to any value from 0 to 255.
Using the BCC
To change the signaling VPI number, navigate to the signaling prompt (for
example,
box; atm/11/1; signaling/11/1
) and enter:
vpi
<integer>
integer
is the VPI number that you want the signaling VC to use.
For example, the following command changes the signaling VPI number to 8:
signaling/11/1#
vpi 8
signaling/11/1#
To change the ILMI VPI number, navigate to the ILMI prompt (for example,
box; atm/11/1; signaling/11/1; ilmi/11/1
) and enter:
vpi
<integer>
integer
is the VPI number that you want the ILMI VC to use.
For example, the following command changes the ILMI VPI number to 8:
ilmi/11/1# vpi 8
ilmi/11/1#