Configuring ATM and MPLS Services
A-80
117374-C Rev 00
Parameter: Local TCP Port
Path: Configuration Manager > Circuits > Edit Circuits > Edit > MPLS > LDP
Default: 8192
Options: 1 to 65535
Function: S
pecifies the TCP port number that LDP on the label edge router (LER) uses to
establish the TCP connection to the label-switching router (LSR).
Instructions:
Accept the default, 8192, or enter a TCP port number from 1 to 65,535.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.15.1.1.7
Parameter: Remote IP Address
Path: Configuration Manager > Circuits > Edit Circuits > Edit > MPLS > LDP
Default: 0.0.0.0
Options: Any valid IP address
Function: S
pecifies the IP address of the interface on the label-switching router (LSR) that
LDP on the label edge router (LER) uses to establish the TCP connection
.
Instructions: Enter the IP address in dotted-decimal notation.
Bay Networks recommends that
you use the IP address that you used when configuring the IP protocol on the
remote interface.
You can, however, accept the default value, 0.0.0.0, under
specific circumstances (for example, if you are using circuitless IP).
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.15.1.1.8
Parameter: Remote TCP Port
Path: Configuration Manager > Circuits > Edit Circuits > Edit > MPLS > LDP
Default: 8192
Options: 1 to 65535
Function: S
pecifies the remote TCP port number of the label-switching router (LSR) that
the label edge router (LER) uses to establish the TCP connection.
Instructions:
Accept the default, 8192, or enter a TCP port number from 1 to 65,535.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.15.1.1.9