Parameter: SVC Inactivity Timeout Enable
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: Enable
Options: Enable
|
Disable
Function: If you select Enable, the router disables any switched virtual circuits (SVCs) on
which the router receives or transmits no cells for the number of seconds you
specify using the SVC Inactivity Timeout (Secs) parameter.
If you select Disable, the router keeps SVCs open unless you close them by
another method.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.3.2.1.13
Parameter: SVC Inactivity Timeout (Secs)
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: 1200 seconds
Options: 60 to 3600 seconds
Function: If the router receives or transmits no cells on an SVC for this number of
seconds, it closes the SVC, providing that you set the SVC Inactivity Timeout
Enable parameter to Enable.
Instructions: Enter an appropriate time, and be sure to set the SVC Inactivity Timeout Enable
parameter to Enable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.3.2.1.14