Avaya Configuring Frame Relay Services Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking Avaya Configuring Frame Relay Services. Avaya Configuring Frame Relay Services User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 162
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Frame Relay Services

Part No. 117376-B Rev. 00February 1998BayRS Version 12.10Site Manager Software Version 6.10 ConfiguringFrame Relay Services

Strona 3

Configuring Frame Relay ServicesA-4 117376-B Rev. 00Descriptions of Interface ParametersFrame Relay Interface parameters are the same for PVCs and SVC

Strona 4

Site Manager Parameters117376-B Rev. 00 A-5 Parameter: Mgmnt TypePath: Configuration Manager > Protocols > Frame Relay > InterfacesDefault: AN

Strona 5 - Contents

Configuring Frame Relay ServicesA-6 117376-B Rev. 00Parameter: AddressPath: Configuration Manager > Protocols > Frame Relay > InterfacesDefaul

Strona 6 - Incoming

Site Manager Parameters117376-B Rev. 00 A-7 Parameter: Polling IntervalPath: Configuration Manager > Protocols > Frame Relay > InterfacesDefau

Strona 7

Configuring Frame Relay ServicesA-8 117376-B Rev. 00Parameter: Error ThresholdPath: Configuration Manager > Protocols > Frame Relay > Interfac

Strona 8

Site Manager Parameters117376-B Rev. 00 A-9 Parameter: MulticastPath: Configuration Manager > Protocols > Frame Relay > InterfacesDefault: Dis

Strona 9

Configuring Frame Relay ServicesA-10 117376-B Rev. 00Parameter: Congestion TimerPath: Configuration Manager > Protocols > Frame Relay > Interf

Strona 10

Site Manager Parameters117376-B Rev. 00 A-11 SVC LAPF ParametersIf you configure SVCs, LAPF parameters are important to your network. You can edit thes

Strona 11 - 117376-B Rev. 00

Configuring Frame Relay ServicesA-12 117376-B Rev. 00Figure A-3. FR LAPF Parameters WindowTo access the FR LAPF Parameters window:Site Manager Procedu

Strona 12

Site Manager Parameters117376-B Rev. 00 A-13 Parameter: EnablePath: Configuration Manager > Protocols > Interfaces > LAPFDefault: EnableOption

Strona 13

117376-B Rev. 00 xi Figures Figure 2-1. Frame Relay Network ...2-2Figure

Strona 14

Configuring Frame Relay ServicesA-14 117376-B Rev. 00Parameter: Action InitiatePath: Configuration Manager > Protocols > Interfaces > LAPFDefa

Strona 15 - About This Guide

Site Manager Parameters117376-B Rev. 00 A-15 Parameter: T200, Base TimerPath: Configuration Manager > Protocols > Interfaces > LAPFDefault: 15

Strona 16 - Conventions

Configuring Frame Relay ServicesA-16 117376-B Rev. 00Parameter: N200, Max RetriesPath: Configuration Manager > Protocols > Interfaces > LAPFDe

Strona 17 - Acronyms

Site Manager Parameters117376-B Rev. 00 A-17 SVC Signaling ParametersIf you configure SVCs, signaling parameters are important to your network. You can

Strona 18 - Bay Networks Customer Service

Configuring Frame Relay ServicesA-18 117376-B Rev. 00To access the Frame Relay Signaling Parameters window:Site Manager ProcedureYou do this System re

Strona 19 - How to Get Help

Site Manager Parameters117376-B Rev. 00 A-19 Parameter: T303, Setup Message TimerPath: Configuration Manager > Protocols > Frame Relay > Inter

Strona 20

Configuring Frame Relay ServicesA-20 117376-B Rev. 00Parameter: T308, Release TimerPath: Configuration Manager > Protocols > Frame Relay > Int

Strona 21 - Starting Frame Relay

Site Manager Parameters117376-B Rev. 00 A-21 Parameter: T322, Status Enq Retry TimerPath: Configuration Manager > Protocols > Frame Relay > In

Strona 22 - Configuring PVCs and SVCs

Configuring Frame Relay ServicesA-22 117376-B Rev. 00Parameters for PVCsThe following topics give information about configuring PVCs:• Service Name Par

Strona 23 - Configuring an SVC

Site Manager Parameters117376-B Rev. 00 A-23 Figure A-5. Frame Relay Service List Window (for PVCs)To access the Frame Relay Service List window:Site

Strona 25 - Configuring IPX Adjacent Hosts

Configuring Frame Relay ServicesA-24 117376-B Rev. 00Required DLCI Parameter for Each PVCThe Frame Relay PVC Add window (Figure A-6) contains the DLCI

Strona 26 - 1-6 117376-B Rev. 00

Site Manager Parameters117376-B Rev. 00 A-25 To access the Frame Relay PVC Add window:Site Manager ProcedureYou do this System responds1. Click on the

Strona 27 - Frame Relay Overview

Configuring Frame Relay ServicesA-26 117376-B Rev. 00PVC Service Record ParametersThe FR PVC List for Service window (Figure A-7) contains the PVC par

Strona 28 - Introduction

Site Manager Parameters117376-B Rev. 00 A-27 To access the FR PVC List for Service window:Site Manager ProcedureYou do this System responds1. Click on

Strona 29 - Switched Virtual Circuits

Configuring Frame Relay ServicesA-28 117376-B Rev. 00Parameter: Hybrid ModePath: Configuration Manager > Protocols > Frame Relay > Services &g

Strona 30 - Frame Relay Packets

Site Manager Parameters117376-B Rev. 00 A-29 Parameter: ThroughputPath: Configuration Manager > Protocols > Frame Relay > Services > PVCsDe

Strona 31 - 117376-B Rev. 00 2-5

Configuring Frame Relay ServicesA-30 117376-B Rev. 00Parameter: Congestion TimerPath:Configuration Manager > Protocols > Frame Relay > Service

Strona 32 - Management Protocols

Site Manager Parameters117376-B Rev. 00 A-31 Parameter: Congestion MethodPath: Configuration Manager > Protocols > Frame Relay > Services >

Strona 33

Configuring Frame Relay ServicesA-32 117376-B Rev. 00Optional Algorithm Parameter for Each Multiline ConfigurationThe Services Multiline With window (F

Strona 34 - Frame Relay Service Records

Site Manager Parameters117376-B Rev. 00 A-33 This window lets you:• Specify how a multiline circuit distributes traffic by setting the Multiline Algori

Strona 35 - Frame Relay Access Modes

117376-B Rev. 00 xiii Tables Table 2-1. PVC and SVC Protocol and Feature Support ...2-4Table 2-2. How Protocol

Strona 36 - Hybrid Access Mode

Configuring Frame Relay ServicesA-34 117376-B Rev. 00SVC Service Record ParametersThe following sections describe SVC service record parameters.• SVC

Strona 37

Site Manager Parameters117376-B Rev. 00 A-35 Figure A-10. Frame Relay Service List Window (for SVCs)To access the Frame Relay Service List window:Site

Strona 38 - 2-12 117376-B Rev. 00

Configuring Frame Relay ServicesA-36 117376-B Rev. 00Note: You do not have access to the SVC parameters until you set the SVC Support parameter to Ena

Strona 39 - Address Resolution for PVCs

Site Manager Parameters117376-B Rev. 00 A-37 Parameter: SVC Local Party Sub-AddressPath: Configuration Manager > Protocols > Frame Relay > Ser

Strona 40 - Traffic Control

Configuring Frame Relay ServicesA-38 117376-B Rev. 00Parameter: SVC Call BlockPath: Configuration Manager > Protocols > Frame Relay > Services

Strona 41 - Data Compression

Site Manager Parameters117376-B Rev. 00 A-39 Parameter: SVC Inactivity TimerPath: Configuration Manager > Protocols > Frame Relay > Services D

Strona 42 - Congestion Control

Configuring Frame Relay ServicesA-40 117376-B Rev. 00SVC Options ParametersYou can edit SVC Options parameters in the Frame Relay SVC Options Add wind

Strona 43

Site Manager Parameters117376-B Rev. 00 A-41 Parameter: Options NamePath: Configuration Manager > Protocols > Frame Relay > Services > SVCs

Strona 44 - Traffic Shaping

Configuring Frame Relay ServicesA-42 117376-B Rev. 00Parameter: Remote Party Number PlanPath: Configuration Manager (select a connector) > Edit Conn

Strona 45 - Quality of Service

Site Manager Parameters117376-B Rev. 00 A-43 SVC Options List for Service ParametersWhen you have finished editing the Options parameters in the Option

Strona 47 - Traffic Shaping for SVCs

Configuring Frame Relay ServicesA-44 117376-B Rev. 00Parameter: Broadcast ControlPath: Configuration Manager > Protocols > Frame Relay > Servi

Strona 48 - 2-22 117376-B Rev. 00

Site Manager Parameters117376-B Rev. 00 A-45 Parameter: X.213 Data PriorityPath: Configuration Manager > Protocols > Frame Relay > Services &g

Strona 49 - Traffic Shaping Considerations

Configuring Frame Relay ServicesA-46 117376-B Rev. 00Parameter: X.213 Gain PriorityPath: Configuration Manager > Protocols > Frame Relay > Ser

Strona 50 - WCP and CIR Enforcement

Site Manager Parameters117376-B Rev. 00 A-47 Parameter: X.213 Keep PriorityPath: Configuration Manager > Protocols > Frame Relay > Services &g

Strona 51 - Oversubscribing the Interface

Configuring Frame Relay ServicesA-48 117376-B Rev. 00Parameter: LL Core Out ThroughputPath: Configuration Manager > Protocols > Frame Relay >

Strona 52 - 2-26 117376-B Rev. 00

Site Manager Parameters117376-B Rev. 00 A-49 Parameter: LL Core Min In ThroughputPath: Configuration Manager > Protocols > Frame Relay > Servi

Strona 53 - Inactivity Timing for SVCs

Configuring Frame Relay ServicesA-50 117376-B Rev. 00Parameter: LL Core In Committed BurstPath: Configuration Manager (select a connector) > Edit Co

Strona 54 - 2-28 117376-B Rev. 00

Site Manager Parameters117376-B Rev. 00 A-51 Parameter: LL Core In Excess BurstPath: Configuration Manager (select a connector) > Edit Connector win

Strona 55 - Multiline for PVCs

Configuring Frame Relay ServicesA-52 117376-B Rev. 00Parameter: Congestion TimerPath: Configuration Manager (select a connector) > Edit Connector wi

Strona 56 - 2-30 117376-B Rev. 00

Site Manager Parameters117376-B Rev. 00 A-53 Parameter: Congestion MethodPath: Configuration Manager (select a connector) > Edit Connector window &g

Strona 57 - PVC Pass Through

117376-B Rev. 00 xv About This Guide If you are responsible for configuring frame relay, you need to read this guide. Before You Begin Before using t

Strona 58 - Frame Relay Dial Services

Configuring Frame Relay ServicesA-54 117376-B Rev. 00Parameter: WCP EnablePath: Configuration Manager (select a connector) > Edit Connector window &

Strona 59

117376-B Rev. 00 B-1 Appendix BRIP Management for Frame Relay SVCsIP and IPX use RIP to inform network entities of routing topology changes. Both IP a

Strona 60 - 2-34 117376-B Rev. 00

Configuring Frame Relay ServicesB-2 117376-B Rev. 00Table B-1. RIP Parameters IP or IPX RIP EnableIP or IPX RIP Frame Relay SVC Broadcast EnableFrame

Strona 61 - Customizing Frame Relay

RIP Management for Frame Relay SVCs117376-B Rev. 00 B-3 Disabled Enabled or DisabledTransmit RIP timer not applicable; RIP is disabled.Not applicable;

Strona 62 - Selecting a Management Type

Configuring Frame Relay ServicesB-4 117376-B Rev. 00Enabled Disabled Receive Inactivity < RIP When the RIP timer expires: • RIP packets will be sen

Strona 63 - Selecting a DLCI Address Type

RIP Management for Frame Relay SVCs117376-B Rev. 00 B-5 Enabled Disabled Transmit Inactivity < RIP When the RIP timer expires: • RIP packets will

Strona 64 - Selecting Address Length

Configuring Frame Relay ServicesB-6 117376-B Rev. 00Enabled Enabled Receive Inactivity < RIP When the RIP timer expires:• RIP packets will be sent

Strona 65 - Monitoring the Connection

RIP Management for Frame Relay SVCs117376-B Rev. 00 B-7 Enabled Disabled Transmit Inactivity > RIP When the RIP timer expires: • RIP packets will

Strona 67 - Customizing PVCs

117376-B Rev. 00 Index-1Aaccess modes, 2-9Action Initiate parameter, A-14addingPVCs, 3-8PVCs to a service record, 2-9service records, 3-7, 3-20SVCs, 3

Strona 68 - To delete service records:

Configuring Frame Relay Servicesxvi 117376-B Rev. 00 Conventions bold text Indicates text that you need to enter, command names, and buttons in menu

Strona 69

Index-2 117376-B Rev. 00service records, 3-8, 3-21dial backup, 2-32dial-on-demand, 2-32direct mode, 2-10DLCI address length, selecting, 3-4DLCI Number

Strona 70 - Enabling Multicast

117376-B Rev. 00 Index-3LL Core Out Throughput parameter, A-48LMI (Local Management Interface), 2-7, 3-2, A-5Mmanagement protocols. See DLCMImanagemen

Strona 71

Index-4 117376-B Rev. 00Station Type parameter, A-13SVC Call Block parameter, A-38SVC Control parameter, A-43SVC Inactivity Mode parameter, A-39SVC In

Strona 72 - Configuring PVC Pass Through

About This Guide 117376-B Rev. 00 xvii Acronyms ANSI American National Standards InstituteARP Address Resolution ProtocolATM Asynchronous Transfer M

Strona 73

Configuring Frame Relay Servicesxviii 117376-B Rev. 00 OSI Open Systems InterconnectionPRI Primary Rate InterfacePVC permanent virtual circuitQoS qua

Strona 74 - 3-14 117376-B Rev. 00

About This Guide 117376-B Rev. 00 xix Information about customer service is also available on the World Wide Web at support.baynetworks.com . How t

Strona 75 - To enable congestion control:

ii 117376-B Rev. 00 4401 Great America Parkway 8 Federal StreetSanta Clara, CA 95054 Billerica, MA 01821 Copyright © 1998 Bay Networks, Inc. All righ

Strona 76 - 3-16 117376-B Rev. 00

Configuring Frame Relay Servicesxx 117376-B Rev. 00 Bay Networks Educational Services Through Bay Networks Educational Services, you can attend class

Strona 77 - Enabling Compression for PVCs

117376-B Rev. 00 1-1 Chapter 1Starting Frame Relay The quickest way to begin using frame relay on your network is to enable it with default values f

Strona 78 - 3-18 117376-B Rev. 00

Configuring Frame Relay Services1-2 117376-B Rev. 00 You have enabled frame relay. You can now specify the protocols you want to run on this interfac

Strona 79 - Removing Multiline Services

Starting Frame Relay117376-B Rev. 00 1-3 Configuring an SVCTo configure an SVC: 6. Enter a value in the DLCI Number parameter. See Help or the parameter

Strona 80 - Customizing SVCs

Configuring Frame Relay Services1-4 117376-B Rev. 00Configuring Adjacent Hosts for an SVCIf you are configuring IP or IPX for this frame relay service r

Strona 81 - Adding SVCs

Starting Frame Relay117376-B Rev. 00 1-5 Configuring IPX Adjacent HostsTo configure IPX adjacent hosts:4. Click on OK. You return to the IP Adjacent Hos

Strona 82 - 3-22 117376-B Rev. 00

Configuring Frame Relay Services1-6 117376-B Rev. 00Deleting Frame Relay from a PlatformTo delete frame relay from all circuits on which it is current

Strona 83 - Disabling SVCs

117376-B Rev. 00 2-1 Chapter 2Frame Relay OverviewThe following sections present an overview of frame relay.Topic PageIntroduction 2-2Permanent Virtua

Strona 84 - Disconnecting SVCs

Configuring Frame Relay Services2-2 117376-B Rev. 00IntroductionFrame relay is a high-speed, packet-switching WAN protocol that connects geographicall

Strona 85 - To edit LAPF parameters:

Frame Relay Overview117376-B Rev. 00 2-3 Frame relay assumes that networks use transmission lines with low error rates, such as digital transmission m

Strona 86 - To edit Signaling parameters:

117376-B Rev. 00 iii Bay Networks, Inc. Software License Agreement NOTICE: Please carefully read this license agreement before copying or using th

Strona 87

Configuring Frame Relay Services2-4 117376-B Rev. 00PVC and SVC ComparisonTable 2-1 lists the protocols and features that PVCs and SVCs support. Frame

Strona 88 - To set X.213 priority values:

Frame Relay Overview117376-B Rev. 00 2-5 • Command/response bit (C/R)ITU-T (formerly CCITT) standards do not use this bit.• Forward explicit congestio

Strona 89

Configuring Frame Relay Services2-6 117376-B Rev. 00Figure 2-3. Frame Relay Header: 3- and 4-Byte FormatsManagement ProtocolsFrame relay is an access

Strona 90 - 3-30 117376-B Rev. 00

Frame Relay Overview117376-B Rev. 00 2-7 DLCMI supports three standard data link management specifications: LMI, ANSI T1.617 Annex D, and CCITT (now IT

Strona 91 - To enable traffic shaping

Configuring Frame Relay Services2-8 117376-B Rev. 00Frame ProcessingWhen a frame enters a frame relay network, the network performs three steps to pro

Strona 92 - Enabling Compression for SVCs

Frame Relay Overview117376-B Rev. 00 2-9 Multiple Service RecordsInterfaces can have multiple service records, and each service record can contain mul

Strona 93 - To disable compression:

Configuring Frame Relay Services2-10 117376-B Rev. 00Direct Access ModeDirect mode describes a service record with one PVC. In direct access mode, upp

Strona 94

Frame Relay Overview117376-B Rev. 00 2-11 Figure 2-5. Hybrid Mode Configuration, Non-Fully Meshed NetworkUsing Hybrid Mode for Transparent BridgingFig

Strona 95 - Deleting Frame Relay

Configuring Frame Relay Services2-12 117376-B Rev. 00Figure 2-6. Example of a Bridged NetworkIn this example, the bridge receives data from Site A. If

Strona 96

Frame Relay Overview117376-B Rev. 00 2-13 Source RoutingSource routing is the method by which a bridge sends data across two networks. The router supp

Strona 97 - Appendix A

iv 117376-B Rev. 00 its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files

Strona 98 - A-2 117376-B Rev. 00

Configuring Frame Relay Services2-14 117376-B Rev. 00Address Resolution for SVCsFor SVCs, adjacent host configuration including either an E.164 or X.12

Strona 99

Frame Relay Overview117376-B Rev. 00 2-15 Figure 2-7. Big Pipe/Little Pipe TopologyThe central site router sends traffic at its available bandwidth, in

Strona 100 -

Configuring Frame Relay Services2-16 117376-B Rev. 00To use data compression with frame relay, the Compression Control parameter must be set to Enable

Strona 101 - Site Manager Parameters

Frame Relay Overview117376-B Rev. 00 2-17 In the frame relay packet header, there are two bits that the network sets to alert nodes of network congest

Strona 102 -

Configuring Frame Relay Services2-18 117376-B Rev. 00If you enable congestion control and also enable traffic shaping, you can throttle, which means qu

Strona 103

Frame Relay Overview117376-B Rev. 00 2-19 CIR EnforcementCIR enforcement means restricting the speed of outbound traffic to a rate no faster than the C

Strona 104 - A-8 117376-B Rev. 00

Configuring Frame Relay Services2-20 117376-B Rev. 00Using protocol prioritization with traffic shaping creates two levels of queues. For traffic shapin

Strona 105

Frame Relay Overview117376-B Rev. 00 2-21 All traffic that goes to a traffic-shaped VC (VC1 or VC2) is queued as high, normal, or low priority at the VC

Strona 106 - A-10 117376-B Rev. 00

Configuring Frame Relay Services2-22 117376-B Rev. 00If you supply values for the LL Core parameters, the router requests an SVC from the frame relay

Strona 107 - SVC LAPF Parameters

Frame Relay Overview117376-B Rev. 00 2-23 Setting Minimum Acceptable ThroughputThroughput that an SVC actually uses may be less than it requests becau

Strona 108 - A-12 117376-B Rev. 00

117376-B Rev. 00 v Contents About This Guide Before You Begin ...

Strona 109 -

Configuring Frame Relay Services2-24 117376-B Rev. 00• If, however, you are sending frames that exceed the size of the Bc, data travels very slowly be

Strona 110 -

Frame Relay Overview117376-B Rev. 00 2-25 Using Traffic Shaping EffectivelyYou can use traffic shaping at one or both ends of a link, but you must use c

Strona 111

Configuring Frame Relay Services2-26 117376-B Rev. 00• The default number of buffers is 200 per interface.• The software divides the number of buffers

Strona 112 - A-16 117376-B Rev. 00

Frame Relay Overview117376-B Rev. 00 2-27 The FECN and BECN notifications are part of the header in a frame relay data packet. In a big pipe/little pip

Strona 113 - SVC Signaling Parameters

Configuring Frame Relay Services2-28 117376-B Rev. 00When the router establishes an SVC, the inactivity timer value initializes two timers internal to

Strona 114 - A-18 117376-B Rev. 00

Frame Relay Overview117376-B Rev. 00 2-29 Managing Routing Information Protocol (RIP) Over SVCsRIP is a mechanism that IP and IPX use to inform networ

Strona 115

Configuring Frame Relay Services2-30 117376-B Rev. 00The most important part of configuring multiline is setting the PVC DLCI number. This number ident

Strona 116 - A-20 117376-B Rev. 00

Frame Relay Overview117376-B Rev. 00 2-31 The router determines whether to route or bridge the packet, and then uses the corresponding level of addres

Strona 117

Configuring Frame Relay Services2-32 117376-B Rev. 00Figure 2-12 shows a router with an Ethernet interface, and two frame relay interfaces. The frame

Strona 118 - Parameters for PVCs

Frame Relay Overview117376-B Rev. 00 2-33 For More Information About Frame RelayFor more information about frame relay, consult the following document

Strona 119

vi 117376-B Rev. 00 Frame Relay Service Records ...2-8Default S

Strona 120 - A-24 117376-B Rev. 00

Configuring Frame Relay Services2-34 117376-B Rev. 00The following publications provide a less technical introduction to frame relay:Davidson, R., and

Strona 121

117376-B Rev. 00 3-1 Chapter 3Customizing Frame RelayWhen you enable frame relay, default values are in effect for all parameters (for parameter descr

Strona 122 - PVC Service Record Parameters

Configuring Frame Relay Services3-2 117376-B Rev. 00Selecting a Management TypeYou can specify the management protocol that the router and the frame r

Strona 123 -

Customizing Frame Relay117376-B Rev. 00 3-3 Selecting Address Type and LengthYou can specify the data link connection identifier (DLCI) address type an

Strona 124 - A-28 117376-B Rev. 00

Configuring Frame Relay Services3-4 117376-B Rev. 00• The March draft of ADDR Q922 differs from ADDR Q922 in defining an 11-bit DLCI and dropping the D

Strona 125 -

Customizing Frame Relay117376-B Rev. 00 3-5 Monitoring the ConnectionYou can monitor the status of your frame relay network connection by setting:• Ti

Strona 126 - A-30 117376-B Rev. 00

Configuring Frame Relay Services3-6 117376-B Rev. 00Error Threshold and Monitored EventsError threshold and monitored events together establish a crit

Strona 127

Customizing Frame Relay117376-B Rev. 00 3-7 Customizing PVCsUse the sections that follow for guidance in customizing PVCs to meet the requirements of

Strona 128 - A-32 117376-B Rev. 00

Configuring Frame Relay Services3-8 117376-B Rev. 00Deleting Service Records for PVCsTo delete service records: Adding PVCs to Service RecordsYou can

Strona 129

Customizing Frame Relay117376-B Rev. 00 3-9 Deleting PVCs From Service RecordsYou can delete PVCs from already existing service records. After you del

Strona 130 - SVC Service Record Parameters

117376-B Rev. 00 viiUsing Traffic Shaping Effectively ...2-25Using Compression Effe

Strona 131

Configuring Frame Relay Services3-10 117376-B Rev. 00Moving PVCs from One Service Record to AnotherYou can move PVCs on the same line from one service

Strona 132

Customizing Frame Relay117376-B Rev. 00 3-11 Site Manager ProcedureYou do this System responds1. In the Configuration Manager window, click on a port c

Strona 133 -

Configuring Frame Relay Services3-12 117376-B Rev. 00Configuring Hybrid Mode for PVCsHybrid mode allows you to use the same PVCs for both routing and b

Strona 134 -

Customizing Frame Relay117376-B Rev. 00 3-13 Site Manager Procedure You do this System responds1. Configure at least two PVCs, using the directions in

Strona 135

Configuring Frame Relay Services3-14 117376-B Rev. 00Controlling Congestion for PVCsCongestion occurs when a node receives more frames than it can pro

Strona 136 - SVC Options Parameters

Customizing Frame Relay117376-B Rev. 00 3-15 To enable congestion control:Site Manager Procedure You do this System responds1. In the Configuration Man

Strona 137

Configuring Frame Relay Services3-16 117376-B Rev. 00Using Traffic Shaping With PVCsTo use traffic shaping, you configure the Committed Burst, Excess Bur

Strona 138

Customizing Frame Relay117376-B Rev. 00 3-17 Enabling Compression for PVCsTo use data compression with frame relay, first select WCP from the Protocols

Strona 139

Configuring Frame Relay Services3-18 117376-B Rev. 00Grouping Service Records for Multiline ModeYou can configure two or more service records to run in

Strona 140

Customizing Frame Relay117376-B Rev. 00 3-19 Removing Multiline ServicesTo remove multiline services:For information about the Bay Networks proprietar

Strona 141

viii 117376-B Rev. 00 Enabling Multicast ...3-10Config

Strona 142 - A-46 117376-B Rev. 00

Configuring Frame Relay Services3-20 117376-B Rev. 00Customizing SVCsUse the sections that follow for guidance on customizing SVCs to meet the require

Strona 143

Customizing Frame Relay117376-B Rev. 00 3-21 Deleting Service Records for SVCsTo delete service records from a frame relay interface:Adding SVCsTo add

Strona 144 - A-48 117376-B Rev. 00

Configuring Frame Relay Services3-22 117376-B Rev. 005. Supply values for the following SVC parameters. Use Help or the parameter descriptions that be

Strona 145

Customizing Frame Relay117376-B Rev. 00 3-23 Disabling SVCsTo disable SVCs from already existing service records.Site Manager Procedure You do this Sy

Strona 146 - A-50 117376-B Rev. 00

Configuring Frame Relay Services3-24 117376-B Rev. 00Disconnecting SVCsTo disconnect SVCs:Site Manager Procedure You do this System responds1. Click o

Strona 147

Customizing Frame Relay117376-B Rev. 00 3-25 Editing LAPF Parameters for SVCsTo edit LAPF parameters:Site Manager Procedure You do this System respond

Strona 148 - A-52 117376-B Rev. 00

Configuring Frame Relay Services3-26 117376-B Rev. 00Editing Signaling Parameters for SVCsTo edit Signaling parameters:Setting Inactivity Timers for S

Strona 149

Customizing Frame Relay117376-B Rev. 00 3-27 To set inactivity values for a service record:To set the inactivity timer value and mode for a particular

Strona 150

Configuring Frame Relay Services3-28 117376-B Rev. 00Setting X.213 Priorities for SVCsTo set X.213 priority values:6. Choose the SVC option record tha

Strona 151 - Appendix B

Customizing Frame Relay117376-B Rev. 00 3-29 Controlling Congestion for SVCsCongestion occurs when a node receives more frames than it can process, or

Strona 152 - Table B-1. RIP Parameters

117376-B Rev. 00 ixSVC Service Record Parameters ... A-34SVC Service Lis

Strona 153

Configuring Frame Relay Services3-30 117376-B Rev. 00If you enable congestion control, all SVCs on the interface use congestion control and the values

Strona 154 - B-4 117376-B Rev. 00

Customizing Frame Relay117376-B Rev. 00 3-31 Using Traffic Shaping With SVCsTo use traffic shaping, you set parameters specific to throughput, committed

Strona 155

Configuring Frame Relay Services3-32 117376-B Rev. 00Enabling Compression for SVCsTo use data compression with frame relay SVCs, first select WCP from

Strona 156 - B-6 117376-B Rev. 00

Customizing Frame Relay117376-B Rev. 00 3-33 Disabling Compression for SVCsTo disable compression:Site Manager Procedure You do this System responds1.

Strona 157

Configuring Frame Relay Services3-34 117376-B Rev. 00Setting X.213 Priorities for SVCsTo set X.213 priority values:Site Manager Procedure You do this

Strona 158

Customizing Frame Relay117376-B Rev. 00 3-35 Deleting Frame RelayTo delete frame relay from all circuits on which it is currently configured:Site Manag

Strona 160

117376-B Rev. 00 A-1 Appendix ASite Manager ParametersThese topics define frame relay parameters:Interface ParametersThe Frame Relay Interface List wi

Strona 161

Configuring Frame Relay ServicesA-2 117376-B Rev. 00Figure A-1. Frame Relay Interface List Window (for PVCs)If you have configured any SVCs, you see a

Strona 162

Site Manager Parameters117376-B Rev. 00 A-3 Figure A-2. Frame Relay Interface List Window for SVCsTo access the Frame Relay Interface List window:Site

Komentarze do niniejszej Instrukcji

Brak uwag