Configuring ATM and MPLS Services
A-66
117374-C Rev 00
Parameter: Max Connection Control
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Signaling
AAL (SAAL)
Default: 4
Options: 1 to 20
Function: Specifies the SSCOP maximum connection control value. This value sets the
maximum number of times the sender can transmit a BGN, END, RS, or ER
PDU.
Instructions: Accept the default, 4, or enter a value from 1 to 20.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.13
Parameter: Max PD Before Poll
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Signaling
AAL (SAAL)
Default: 25
Options: 1 to 120
Function: Specifies the SSCOP maximum poll data (PD) value. This value sets the
maximum value of the poll data state variable before transmitting a poll PDU.
The poll data state variable increments upon transmission of a sequenced data
(SD) PDU and resets to 0 upon transmission of a poll PDU.
Instructions: Accept the default, 25, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.14