Configuring ATM and MPLS Services
A-4
117374-C Rev 00
Edit MPLS Connector Window
The Edit MPLS Connector window acts as a control access point for all MPLS
parameters. This window provides information specific to each individual MPLS
interface.
For any given interface, the Edit MPLS Connector window provides two buttons:
•LDP
•MLM
By clicking on one of these buttons, you can access and edit the parameters
associated with that specific MPLS interface.
To access parameters from the Edit MPLS Connector window:
1.
In the Configuration Manager window, click on an ATM link module
interface (labeled ATM1).
The Select Connection Type window opens.
2.
Click on MPLS.
The Edit MPLS Connector window opens.
3.
Click on the appropriate attribute category.
Using the Menu Path
The Protocols menu in the Configuration Manager window provides global
interface and signaling information about every ATM interface on the router. For
example, if you configure four ATM link modules on the router, and you select
Protocols > ATM > Interfaces, the ATM Interface List window displays all four
ATM interfaces that you configured on the router.
Note:
The Protocols menu does not provide access to MPLS parameters. You
must access these parameters using the window path.