Customizing Signaling
117374-C Rev 00
5-19
disconnect-timer TDisc 4 1 to 180 Specifies the SAAL Data Link Disconnect timer
value (in seconds). This internal timer alerts upper
layers that the link is down. The timer begins if the
entire link goes down for any reason.
When the link goes down, the SAAL sends a
DISCONNECT REQUEST message to the
upper-layer application manager. The SAAL sends
a disconnect request every time the SAAL Data
Link Disconnect timer expires and continues to
send this message until the link becomes
operational.
drop-party-tx-
timer
T398 4 1 to 24 Specifies the Drop Party Sent timer value (in
seconds). This timer applies to multipoint
connections only and begins when the circuit sends
a DROP PARTY message to a party (the receiver of
the message) on the network.
The Drop Party Sent timer stops when the circuit
receives a DROP PARTY ACKNOWLEDGE
message (indicating that the end point used for the
party has been released) or a RELEASE message
(indicating that the end point used for the party has
been released and there are no remaining parties).
(continued)
Table 5-1. Signaling Timer Descriptions
(continued)
BCC
Name
Site
Manager
Name
Default
Value Range Description
Komentarze do niniejszej Instrukcji