Configuring ATM and MPLS Services
5-42
117374-C Rev 00
Using the BCC
To change the PCR value for the signaling VC, navigate to the signaling VC
prompt (for example,
box; atm/11/1; signaling/11/1; signaling-vc/11/1/0/5
) and
enter:
pcr
<integer>
integer
is the PCR value that you want the signaling VC to use.
For example, the following command changes the PCR value to 8000:
signaling-vc/11/1/0/5# pcr 8000
signaling-vc/11/1/0/5#
To change the PCR value for the ILMI VC, navigate to the ILMI VC prompt (for
example,
box; atm/11/1; signaling/11/1; ilmi-vc/11/1/0/16) and enter:
pcr
<integer>
integer
is the PCR value that you want the ILMI VC to use.
For example, the following command changes the ILMI VC PCR value to 8000:
ilmi-vc/11/1/0/16# pcr 8000
ilmi-vc/11/1/0/16#