System Administration
8-59
The default value, 2, enables external clocking. The new value, 1, enables internal
clocking.
Enter the following to display the new value:
get wfHssiEntry.wfHssiInternalClkTestMode.4.1
The Technician Interface displays
wfHssiEntry.wfHssiInternalClkTestMode.4.1 = 1
Be sure to enter the following to set the variable back to external clocking to use
the external clock source:
set wfHssiEntry.wfHssiInternalClkTestMode.4.1 2;commit
Responding to QENET Underflow Errors
Transmit underflow errors can occur when a QENET link module is connected to
a FRE module and all four ports are transmitting. This often occurs when non-
SNAP encapsulated frames received from an FDDI ring are routed out the
interface of a QENET. An example of such a frame is a Novell proprietary
encapsulated frame on FDDI.
The wfCSMACDUfloTx attribute in the wfCSMACDEntry MIB object shows the
number of transmit underflow errors. These errors result in other stations
detecting CRC errors.
Enter the following Technician Interface command for each of the four connectors
only if you are experiencing transmit underflow errors as described above:
set wfCSMACDEntry.wfCSMACDAlignmentMode.<slot no.>.<connector>
1;commit
Then save the configuration with these changes to the configuration file.
When you set the wfCSMACDAlignmentMode attribute to 1 (ALIGN_ALL), the
router realigns the nonoptimally aligned frames before transmitting them.
When you set the wfCSMACDAlignmentMode attribute to 3 (DISABLED), the
router transmits the nonoptimally aligned frames without realigning them first.