Przeglądanie stron 48
Configuring the Console Port
114088 Rev. A 2-3
Using the set Command
Enter one of the following Technician Interface commands to configure a console
port parameter:
set wfSerialPort Entry.
<attribute_name>.<port_no.> <option>
set wfSerialPort Entry.
<attribute_no.>.<port_no.> <option>
Example:
The following commands set the Parity parameter to Odd:
set wfSerialPortEntry.wfSerialPortParity.1 2
or
set wfSerialPortEntry.10.1 2
set
Refers to the Technician Interface set command. You
must have Manager access to issue a
set command.
wfSerialPortEntry
Refers to the MIB attribute name associated with all
serial port parameters.
<attribute_name>
Is the MIB attribute name associated with one of the
serial port parameters.
<attribute_no.>
Is the MIB attribute number associated with one of
the serial port parameters.
<port_no.>
Is the number of the serial port you are configuring.
<option>
Is the new setting taken from the Options or Range
list.
Note: You can use s instead of set.