Avaya Using Technician Interface Software Instrukcja Użytkownika Strona 163

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 366
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 162
Accessing the MIB
114088 Rev. A 7-9
Saving the Configuration
You can copy all MIB values from operating RAM to a configuration file for later
retrieval. You use the
save config command to copy the configuration in memory
to the default configuration file or to an alternative configuration file. Enter the
following, where <filename> is the name of the file you are creating to store the
configuration:
save config
<vol>
:
<filename>
Examples:
Refer to “Booting the Router” in Chapter 8 to load a configuration from a file.
Using the MIB-II Counter
You can use the MIB-II counter feature with Version 8.10 and later router
software. The feature enables you to track the number of packets each circuit in
the Bay Networks router processes at the data link layer.
You can enable the Bay Networks MIB to count all incoming and outgoing
packets by using the
set and commit commands with the following parameter.
If you enter: The system:
save config 2:config
Overwrites the default configuration file config on
Volume 2 with the configuration in memory.
save config 2:config.2 Creates an alternate configuration file named con-
fig.2
on Volume 2 and stores the configuration resid-
ing in memory in this file.