Managing Events
114088 Rev. A 6-3
To enable the router to read only certain messages from the events log to the
console display, add read filter arguments to the
log command. You can select
or specify event types by
-- Entity code
-- Severity level
-- Slot number
-- Event date
-- Event time
-- Event number or number range
Applying Write Filters to the Events Log
During normal operation, the events log captures all event messages generated
internally by the router. However, for troubleshooting purposes only, use the
log
command to
Include specific event messages in the events log.
Exclude specific event messages from the events log.
Specify the
log command as follows:
log [-i | -x ] [-e
<entity>
] [-f
<severity>
] [-s
<slot_ID>
]
-i = Include the -e, -f, and/or -s options that follow.
-x = Exclude the -e, -f, and/or -s options that follow.
Note: You can add the -e, -f, and -s arguments to the log command in any
order.