Avaya Troubleshooting Routers Instrukcja Naprawy Strona 171

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 170
Reading the Event Log
A-19
The following messages appear even if you did not connect a modem to the router.
Unlike V.25bis, Raise DTR does not look for a pin signal to detect whether the
port is attached to a modem.
# 39: mm/dd/yy 14:14:04.104 INFO SLOT 2 MODEMIF Code: 52
Connector COM2: Circuit has been brought up.
# 40: mm/dd/yy 14:14:04.104 DEBUG SLOT 2 SWSERV Code: 46
Line Mgr received line ready for line 2
# 41: mm/dd/yy 14:14:04.104 INFO SLOT 2 SWSERV Code: 10
Sync Line 2 available for dial on demand pool 2.
# 42: mm/dd/yy 14:14:04.108 INFO SLOT 2 SYNC Code: 11
Connector COM2 providing LLC1 service.
# 43: mm/dd/yy 14:14:04.636 DEBUG SLOT 2 SWSERV Code: 46
Connector COM2: FSM State: RDTR_WAIT_DATA_OR_IND(1)
Connector COM2: FSM Event: RDTR_EVENT_CD_UP(6); isdn flags: 0x24
# 44: mm/dd/yy 14:15:07.770 INFO SLOT 2 SWSERV Code: 23
Data received for dial on demand circuit 3.
The log messages stop here until you connect and turn on a modem. After you do
this, the router raises DTR to signal the local modem to dial the phone number of
the remote modem. The router then pings the remote side of the dial-on-demand
link, and displays a “data available” message when it receives a response.
# 45: mm/dd/yy 14:15:07.774 DEBUG SLOT 2 SWSERV Code: 46
Connector COM2: FSM State: RDTR_WAIT_DATA_OR_IND(1)
Connector COM2: FSM Event: RDTR_EVENT_DATA_AVAIL(5); isdn flags: 0x2c
# 46: mm/dd/yy 14:15:07.774 TRACE SLOT 2 MODEMIF Code: 34
Connector COM2: DATA Available.
The software assigns a valid circuit number to the line.
# 47: mm/dd/yy 14:15:07.774 DEBUG SLOT 2 SWSERV Code: 44
SW Sent you are cc 3 message to line 2
# 48: mm/dd/yy 14:15:07.782 INFO SLOT 2 SWSERV Code: 7
Dial on demand circuit being established on line 2.
The router waits for DSR to come up to indicate the modem established
connection to the remote node.
# 49: mm/dd/yy 14:15:32.552 DEBUG SLOT 2 SWSERV Code: 46
Connector COM2: FSM State: RDTR_WAIT_FOR_DSR(2)
Connector COM2: FSM Event: RDTR_EVENT_DSR_UP(3); isdn flags: 0x2e
DSR is up.
# 50: mm/dd/yy 14:15:32.552 TRACE SLOT 2 MODEMIF Code: 54
Connector COM2: DSR has come up.
# 51: mm/dd/yy 14:15:32.552 INFO SLOT 2 MODEMIF Code: 31
Connector COM2: Connection established.
Przeglądanie stron 170
1 2 ... 166 167 168 169 170 171 172 173 174 175 176 ... 253 254

Komentarze do niniejszej Instrukcji

Brak uwag