Configuring and Customizing IP
308627-14.20 Rev 00
3-65
Specifying the Time Interval Between Advertisements
You can use the BCC or Site Manager to specify the minimum and maximum
number of seconds between advertisements. The default values for the minimum
and maximum intervals are 450 and 600 seconds, respectively.
Using the BCC
To specify the minimum and maximum number of seconds between
advertisements, go to the Router Discovery prompt on an IP interface (for
example,
box; eth 2/2; ip/2.2.2.2/255.255.0.0; rdisc
) and enter:
min-interval
<interval>
max-interval
<interval>
interval
is any integer.
For example, the following command sets the minimum and maximum intervals
to 550 and 750 seconds, respectively, on interface 2.2.2.2:
rdisc/2.2.2.2#
min-interval 550 max-interval 750
rdisc/2.2.2.2#
4. Set the Broadcast Type parameter. Click
on Help or see the parameter description
on page A-33.
5. Click on Apply, and then click on Done. You return to the Configuration Manager
window.
Site Manager Procedure
(continued)
You do this System responds