GeoTel Features User Manual TCAD Alarm Messages
P0602482 Ver. 04.03 Avaya Page 447
Alarms, Diagnostics and Statistics Management (ADSM)
failed to initialize
• The TMS Alarms Diagnostics and System Monitor (ADSM) failed to
initialize. See “TMS Initialization” on page 451.
Phase Lock Loop Controller (PLL) failed to initialize
• See “TMS PLL” on page 451.
Digital Communications Controller (DCC) failed to
initialize
• The DCC failed to initialize and none of the spans will load. See “TMS
Initialization” on page 451.
The Monitor (MON) failed to initialize
• The Monitor checks messages between the TMS control processor and the
DSPs. It failed to initialize. See “TMS Initialization” on page 451.
Failed to initialize a TMS Card
• Something failed while loading the software. See “TMS Initialization” on
page 451.
Resource Set Manager (RSET) unable to spawn processes
• Software process failed to initialize. See “TMS Memory” on page 451.
Unable to initialize the TMS base Card
• The Base TMS, not including any daughter card, failed to initialize. See
“TMS PLL” on page 451.
Unable to initialize a Multi DSP Module (MDM) card
• The MDM hardware initialization failed. Depending on the configuration of
the card and software, this may or may not affect TMS usability. If the
software configuration does not require the use of all of the DSP resources on
the TMS, the system may still function properly. See “TMS Resources” on
page 452.
Description : Failed to initialize the Analog Line
Interface (ALI)
• See “TMS Initialization” on page 451.