VENGINE 28003
MESSAGE
[Para <block_name>/<1>] Invalid length (<length>), function/
for '<convert-from-binary/ convert-to-binary/ pack-pace'>
SEVERITY
3
PROBABLE CAUSE
The application attempted to use an invalid length parameter for the specified
function. The valid range for a length parameter depends on the call function:
ACTION
Specify a length within the valid range for a call function. Refer to the PeriProducer
User’s Guide for details on the call function parameters.
Call Function Valid Range
convert-from-binary 1-4
convert-to-binary 1 to the maximum string length
pack-pace Message dependent