VENGINE 29011
MESSAGE
[Para <block_name>/<1>] Executable for Program <name>
outdated and has to be recreated
SEVERITY
3
PROBABLE CAUSE
VENGINE attempted to start an application that was made (and compiled) with an
older version of PeriProducer.
ACTION
Port the older application to the latest PeriProducer and recompile it.
NOTES
There may be transition issues with porting older applications to the most recent
PeriProducer. Refer to the PeriProducer Release Notes for information.