Creating Line Pools
114062 Rev. A 7-33
Parameter: Clear Alarm Threshold (seconds)
Default: 2 seconds
Range: 2 to 10 seconds
Function: Specifies the clear time for performance failure conditions. If the defect or
anomaly clears within this time interval, MCE1 records a
performance-cleared condition and logs an event message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.8
Parameter: International Bit
Default: Disable
Options: Enable
| Disable
Function: Specifies whether or not to set the international bit in the E1 frame.
Instructions: Select Enable to set the international bit, or select Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.15
Parameter: Line Impedance
Default: 120 Ohm
Options: 120 Ohm
| 75 Ohm
Function: Specifies Line impedance for the ASN MCE1 net module. This parameter
only appears for the ASN MCE1 module.
Instructions: Set the line impedance.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.20