Page 34 # P0602566 Ver: 2.7
where the selected language is spoken. The countries in the list change
dynamically as different languages are chosen.
English displays countries United States and United Kingdom.
French displays countries France and Canada.
Spanish displays countries Spain, Mexico and Puerto Rico.
6. To configure miscellaneous settings for the selected user, click on the
C
ONFIGURE... button. The Miscellaneous Properties of
User screen appears.
7. Modify the parameters as required. Click O
K to save the changes in the
Miscellaneous Properties of User screen. This saves the
changes locally. To permanently save the changes made, click the O
K
button in the parent screen.
Fault Beep Timer (in second)—Displays the time interval (in seconds)
between two beeping of FAULT_IMMED_ACK faults.
For example, if this setting is 5 seconds and a fault of occurs, the user will
hear a beep every 5 seconds until the fault is acknowledged.
Fault Ignore Ack. Timer (in hour)—Displays the time interval (in hours)
during which a user has to acknowledge a FAULT_IMMED_ACK fault.
For example, the Ignore Ack Timer is set to 1 hour and a fault
occurs at 1pm, and then a second fault occurs at 2 pm. If at 2:30 pm, the
user acknowledges the faults, only the second fault is displayed. This is
because the first fault occurred earlier than 1 hour before the user
acknowledged the fault. However, every fault, whether acknowledged or
not, is recorded in the log file.