Installing Synchronous Net Modules in an ASN Platform
Requirements for European Operation2 BNX Software Version <x.x> Test Part Number
The power drawn from the host chassis combined with that required for any other
net modules and accessories must be within the power rating of the host chassis.
You must install the net modules so as not to impair the integrity of the network
protection from hazardous voltages used or generated internally by the host
chassis.
Clearances and Creepage Distances
You must maintain the clearances and creepage distances (shown as X and Y,
respectively, in Table B-2 and Figure B-1) between the net module and
• The host chassis in which it is installed
• Any adjacent net modules installed in the host chassis
The exception to this rule is the edge connector, which is located in the host
chassis backplane, where no minimum distance applies.
The creepage distances apply to the normal office environment. When the local
environment within the host chassis is subject to conductive pollution or dry
nonconductive pollution that could become conductive due to condensation, the
creepage distances shown in parentheses in Table B-2 will apply.
Table B-2. Net Module Clearances and Creepage Distances
Clearance (X) Creepage (Y)
Voltage Used or Generated by Other
Parts of the Host or Expansion Card
2.0 mm 2.4 (3.8) mm Up to 50 V rms or V dc
2.6 mm 3.0 (4.8) mm Up to 125 V rms or V dc
4.0 mm 5.0 (8.0) mm Up to 250 V rms or V dc
4.0 mm 6.4 (10.0) mm Up to 300 V rms or V dc