Installing Synchronous Net Modules in an ASN Platform
Cabling Requirements for the Net Modules8 BNX Software Version <x.x> Test Part Number
Table A-6. Pin-to-Pin Connections for the 50-Pin to RS-422 Cable
(Order No. 7937)
Bay Networks Termination Remote Termination
Signal Pin to Pin Signal
Data Carrier Detect- 34 31 Receiver Ready B
Data Carrier Detect+ 9 13 Receiver Ready A
Send Data+ 2 4 Send Data A
Send Data- 27 22 Send Data B
Receive Timing+ 11 8 Receive Timing A
Receive Timing- 36 26 Receive Timing B
Send Timing+ 10 5 Send Timing A
Send Timing- 35 23 Send Timing B
Receive Data+ 3 6 Receive Data A
Receive Data- 28 24 Receive Data B
Clear to Send- 30 27 Clear to Send B
Clear to Send+ 5 9 Clear to Send A
Request to Send+ 4 7 Request to Send A
Request to Send- 29 25 Request to Send B
Data Set Ready+ 6 11 Data Mode A
Data Set Ready- 31 29 Data Mode B
Terminal Ready+ 8 12 Terminal Ready A
Terminal Ready- 33 30 Terminal Ready B
Terminal Timing+ 12 17 Terminal Timing A
Terminal Timing- 37 35 Terminal Timing B
Send Common 49 37 Send Common
Signal Ground 48 19 Signal Ground
Internal Wire Connections
Pin 46 (UNBE) > 48 (SGRD) Pin 20 > 37
Pin 13 > 38
Pin 14 > 39