Configuring Frame Relay Services
2-28 117376-B Rev. 00
When the router establishes an SVC, the inactivity timer value initializes two
timers internal to the router: the one that monitors data the router transmits, and
one that monitors data the router receives. The inactivity timer mode defines how
the timers restart. T
able 2-4 shows the various ways you can set these parameters,
and the effect each combination has on disconnecting SVCs.
For instructions on setting these values for the inactivity parameters, see
Cha
pter 3, “Customizing Frame Relay.”
Transmit Inactivity Timer and Protocol Priority No-Reset Filter
A Protocol Priority filter with a No-Reset action affects the operation of the timer
that monitors data the router transmits. Normally this timer restarts for timer
modes Both, Either, or Transmit Only. But data the router transmits over an SVC
that matches a Protocol Priority filter with a No-Reset action does not restart the
transmit inactivity timer. This may cause the SVC to disconnect even though it is
transmitting data.
Table 2-4. Inactivity Timer and Inactivity Timer Mode Interaction
Inactivity Timer Mode Inactivity Timers Used Disconnect SVC
Both Directions Transmit and Receive When both timers expire (no data
transmitted, AND no data received
during the timer interval).
Either Direction Transmit and Receive When either timer expires (no data
transmitted OR no data received
during the timer interval.
Transmit Only Transmit When the transmit timer expires (no
data transmitted during the timer
interval).
Receive Only Receive When the receive timer expires (no
data received during the timer
interval).