Site Manager Parameters
117376-B Rev. 00 A-41
Parameter: Options Name
Path: Configuration Manager > Protocols > Frame Relay > Services > SVCs > Add
Default: None
Options: <line number>.0.<circuit number>
Function: Identifies the options record.
Instructions: Site Manager assigns a unique name in the format given. There is no need to
change this value.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.10.1.34
Parameter: Remote Party Number
Path: Configuration Manager (select a connector) > Edit Connector window > Edit
Circuit > Services > Frame Relay Service List window > SVCs > Add
Default: None
Options: Any display string.
Function: Specifies the outbound called party number, which is also the inbound calling
party number.
Instructions: Enter the number.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.10.1.7
Parameter: Remote Party Sub-Address
Path: Configuration Manager (select a connector) > Edit Connector window > Edit
Circuit > Services > Frame Relay Service List window > SVCs > Add
Default: None
Options: Any display string.
Function: The outbound called party sub-address, which is also the inbound calling party
sub-address.
Instructions: Enter the number.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.10.1.8