Configuring WAN Line Services
A-64
308648-14.00 Rev 00
Parameter: BofL Timeout
Path: Configured FE1 Connector > Adapter Module FE1 Logical Lines
Default: 5 seconds
Options: 1 to 60 seconds
Function: Specifies the time between transmissions of Breath of Life messages from this
synchronous interface. Timeout will occur if five periods elapse without both a
successful frame transmission and a successful reception. When timeout
occurs, the synchronous line will be disabled and re-enabled automatically.
For example, if you set this parameter to 5 seconds, then the interface must
successfully transmit and receive a frame within 25 seconds. Timeout occurs in
25 seconds.
This parameter is valid only if BofL is set to Enable.
Instructions: Either accept the default, 5 seconds, or specify a new value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.8
Parameter: MTU Size (bytes)
Path: Configured FE1 Connector > Adapter Module FE1 Logical Lines
Default: 1600 bytes
Options: 3 to 4608 bytes
Function: Specifies the largest frame (Maximum Transmission Unit) that the router can
transmit on this line.
Instructions: Set this parameter to a value appropriate for your network. For X.25, use a value
at least 5 bytes more than the maximum packet size for the packet level.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.9