Configuring WAN Line Services
A-10
308648-14.00 Rev 00
E1 Line Parameters
You access the E1 line parameters from the Configuration Manager window.
Parameter: V.54 Timer
Path: COM Connector > Edit DSU/CSU > Edit DSU CSU Parameters
Default: 0
Options: 0 to 255 seconds
Function: Sets the duration, in seconds, for the loopback testing specified in the V.54
Loopback parameter. Zero (0) indicates that loopback testing runs indefinitely.
Instructions: Specify the number of seconds for loopback testing to run.
If the only connection with the remote router is through the DSU/CSU interface,
be sure to specify a nonzero value, since loopback testing leaves the router
unable to communicate with the remote router.
MIB Object ID: 1.3.6.1.4.1.18.3.4.30.1.1.13
Parameter: Enable
Path: E1 Connector > Edit Line > Edit E1 Parameters
Default: Enable
Options: Enable
|
Disable
Function: Enables or disables the E1 line.
Instructions: Set to Disable if you want to disable the E1 line.
MIB Object ID: 1.3.6.1.4.1.18.3.4.11.1.2