Site Manager Parameters
309249-14.00 Rev 00
A-7
MPS Operational Parameters
This section describes the operational parameters you can customize for a new
MPS.
Parameter: MPS Ctrl ATM Address Selector Byte
Path: Configuration Manager > Circuits > Edit Circuits >
Edit
>
ATM
>
MPOA
Server Attributes
>
MPS
>
Add
Default: None
Options: 00 to FF
Function: Specifies a 1-byte selector field for the MPS. You need only configure this
parameter when the control ATM address generate mode is manual.
The MPS uses the end-station identifier of the service record control ATM
address user part. However, each MPS must have a unique selector field value.
Instructions: Enter a unique 1-byte selector field for the MPS.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.10.2.5
Back to “Configuring a Unique Selector Byte for an MPS Address” on page
3-14.
Parameter: Enable/Disable
Path: Configuration Manager > Circuits > Edit Circuits >
Edit
>
ATM
>
MPOA
Server Attributes
>
MPS
Default: Enable
Options: Enable
|
Disable
Function: Enables or disables the selected MPS.
Instructions: Accept the default, Enable, if you want the MPS to remain enabled on this
interface. Select Disable if you do not want the MPS enabled on this interface.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.10.1.1.2
Back to “Disabling and Reenabling MPOA Servers” on page 3-8.