Configuring Frame Relay Services
3-10
117376-C Rev. 00
Monitored Events
To set monitored events:
1.
Navigate to the dlcmi prompt.
For example:
box; serial/1/2; frame-relay/1/2; dlcmi
2.
Enter the
monitored-events
command and the value you want the
network to use.
monitored-events
<integer>
<integer>
is the number of monitored events that together with the error
threshold establishes a criterion to evaluate the quality of the router/frame
relay connection. The legal values are 1 to 5000 events, and the default is 4.
For example, the following command line sets the value at 10 events:
dlcmi/1/2# monitored-events 10
dlcmi/1/2#
Using Site Manager
To specify error threshold and monitored events values:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Interfaces
. The Frame Relay Interfaces window
opens.
4. Set the following parameters, using
Help
or the parameter descriptions that begin
on page A-7:
• Polling Interval
• Full Enquiry Interval
• Error Threshold
• Monitored Events