Configuring Frame Relay Services
3-4 117376-A Rev. A
Adding PVCs
You can add PVCs to already existing service records. You can add PVCs either
individually, or in a range. If you want to add one PVC, enter one DLCI number.
If you want to add several PVCs, enter the appropriate range of DLCI numbers in
the format < lowest DLCI number> - < highest DLCI number> as shown in the
following table.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on Edit Circuit. The Frame Relay Circuit Definition
window opens.
3. Click on Services. The Frame Relay Service List window
opens.
4. Click on PVCs. The Frame Relay PVC List window
opens.
5. Click on Add. The Frame Relay PVC Add window
opens.
6. Click on the DLCI Number parameter and
enter the DLCI number, or, if you want to
add more than one PVC, enter a range of
numbers in the format
<lowest DLCI
number> - <highest DLCI number>.
7. Click on OK. The Frame Relay PVC List window
reopens. Note that it now lists the PVCs
you have just created.
Komentarze do niniejszej Instrukcji