49
Release Notes for BayStack Operating System Switching Software (BoSS) 3.1
Additional entries in non-volatile system log
Table 23
Log Entry
Stack manager event JOIN STACK (module id = <physical id>)
Explanation
Informational message declaring that the module has joined the
stack
Diagnostic Info
N/A
Table 24
Log Entry
Stack manager event LEAVE STACK (module id = <physical id>)
Explanation
Informational message declaring that the module has just left the
stack.
Diagnostic Info
This may or may not be a failure depending on the circumstances. If
you just disconnected both cascading cables on the unit, then this is
a normal behavior. Otherwise, you may need to investigate why the
unit left the stack.
Table 25
Log Entry
Switch Reset, Ring Check Error, Global Reset Count
Explanation
A soft reset has occurred when the global reset counter value is
<number>. The stack manager on the base unit reset because it did
not receive back the ring any of the ring check packet that it
transmitted and the ring discovery algorithm fails to form a ring.
Diagnostic Info
This event should not normally occur unless there have been multiple
resets of the units on the stack which result in the communication
path being broken repeatedly.
Table 26
Log Entry
Switch Reset, Ring Discovery Error, Global Reset Count
Komentarze do niniejszej Instrukcji