Przeglądanie stron 324
Dial Service Parameters
114062 Rev. B A-55
PPP Circuit Options Parameters (Dial Backup)
Parameter: Circuit Type
Path: Dialup > Backup Circuits > PPP > Primary Circuit Definition > Cct Type >
Circuit Options
Default: Normal
Options: Primary
| Normal
Function: Specifies whether the circuit over the selected leased line uses dial backup
service. This line is not part of the backup pool. For a standard leased circuit,
the router does not provide a backup if the original circuit fails. For a primary
circuit, the router provides a backup to carry the data.
Instructions: Accept the default, Normal, if you do not want a backup circuit for the data.
Select Primary if you want to use dial backup service.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.1.1.31
Parameter: Backup Pool ID
Path: Dialup > Backup Circuits > PPP > Primary Circuit Definition > Cct Type >
Circuit Options
Default: None
Range: 1 to 255
Function: Identifies the backup pool for the primary circuit.
Instructions: If you select Primary for the Circuit Type parameter, enter the ID of the backup
pool that this circuit should use. If you accept the default, Normal, for the
Circuit Type parameter, do not enter a value for this parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.5