Sample Display - show ds1e1 clock
DS1E1 Clock Status:
-------------------
DS1E1 ModuleEntry MIB:
----------------------
Current Primary Secondary
Slot Mod clock clock clock
---- --- ---------- ---------- ----------
5 1 Loop1 Loop1 Internal
*********************************************************
*** ClockEntry MIB pre-empts ModuleEntry MIB settings ***
*********************************************************
DS1E1 ClockEntry MIB:
---------------------
Current Primary Secondary
Slot Mod Port clock clock clock
--- --- ------ ---------- ---------- ----------
5 1 905101 Internal Internal Internal
5 1 905102 Loop4 Loop4 Internal
5 1 905103 Loop4 Loop4 Internal
5 1 905104 Loop4 Loop4 Internal
DS1E1 Clock Status:
-------------------
Loop1 Loop2 Loop3 Loop4 External
Slot Mod clock clock clock clock clock
---- --- ----------- ----------- ----------- ----------- -----------
5 1 Present Present Present Present Not Present
1 entry in table.