Secondary Tx Clock Defines the type of secondary T1 transmit timing source to be used
when a T1 primary transmit clock fails:
Loop - Timing from the T1 port.
Local - Internal timing from the FT1/T1 adapter module.
Current Tx Clock Defines the T1 transmit timing source currently configured:
Loop - Timing from the T1 port.
Local - Internal timing from the FT1/T1 adapter module.
Rate Number of bits per second at which voice, data, and video signals
are transmitted over the T1 line.
DS0 Map DS0 channels configured for the DS1 frame; ranges from 1 to 24.