Using Technician Interface Scripts
2-430
303560-A Rev 00
system errors
Displays statistical information about general interface errors for all circuits or for a
specific circuit.
Sample Display - show isdnbri system errors
ISDN BRI Module System Errors:
------------------------------
Timer 3 Timer 4
Slot Conn Timeouts Timeouts
---- ---- ---------- ----------
1 12 11 11
1 32 0 0
Slot Slot identifier; ranges from 1 to 14.
Conn Connector’s instance identifier; ranges from 1 to 4.
Timer 3 Timeouts Number of Timer 3 timeouts that occurred for the circuit.
Timer 4 Timeouts Number of Timer 4 timeouts that occurred for the circuit.