Avaya DECT Messenger Fundamentals - Communication Server 1000 Instrukcja Użytkownika Strona 91

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 168
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 90
Figure 20: Database handling with eCONFIG on the DECT Messenger Server PC (Local)
After you start the eCONFIG for the first time, a copy is made of the configuration database of
DECT Messenger (Messenger_CFG.MDB). This copy is stored in the eCONFIG directory: C:
\SOPHO Messenger@net eConfig\Mdb with the file name: Messenger_WRK.cfg. After you
make configuration changes using the eCONFIG, these changes are stored in the copy of the
database (Messenger_WRK.cfg) in the eCONFIG directory. To make these changes active,
you must:
Making configuration changes active
1. Close down eTM, eKERNEL, eWEB, and so on.
2. Close eCONFIG using the menu option File > Exit. The operational database is
deleted automatically. The database from the eCONFIG is stored into the DECT
Messenger directory, and renamed to Messenger_CFG.MDB, which is the new
operational database.
3. Restart the modules that you closed down; your new configuration is active.
Note:
After you make changes in the copy of the database in eCONFIG, ensure that nobody else
is making changes in the operational database, as that causes an error if you try to shut
down the eCONFIG and write the database back into the DECT Messenger directory.
Note:
If there are Monitored devices in the active configuration, and one of these devices initiates
a follow-me, the diversion information is stored in the active database. Therefore, you cannot
restore the eCONFIG database, and any changes you have made are lost (except for the
changes in Users, Groups, and Devices, as explained in the following paragraph).
If you make changes in Users, Groups or Devices, these changes are stored in the eCONFIG
database (Messenger_WRK.cfg) and in the operational database (Messenger_CFG.mdb),
and are therefore immediately activated. Saving this information into the operational database
is done by sending an XML string from the eCONFIG to the eKERNEL. The eKERNEL stores
this information into the operational database.
• Starting up the eCONFIG again
After you start the program again, eCONFIG finds a database in its directory. eCONFIG asks
you whether you want to continue with this database or retrieve a fresh copy from the
Using eCONFIG
DECT Messenger Fundamentals March 2012 91
Przeglądanie stron 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 167 168

Komentarze do niniejszej Instrukcji