Figure 26: Groups in an input module
A Group name must match a Group name that comes from the input module. In this
example, the Group name (Fire1) must match the Group name that is assigned to the
input contact (01) in
Figure 26: Groups in an input module on page 100. Under the Group
name Fire1, two Members are listed, which are actual output Devices (Device 2000 and
Device DO_02_01).
If a user presses the button connected to Contact 01, the Input Program eIO generates
an Alarm for group Fire1. eIO sends this information to the eKERNEL, where a group is
present with the name Fire1 for the eIO Module. The alarm is passed on to the group
Members: 2000 and DO_02_01.
• Alarm
The Alarm description also comes from the input program, and can be the identifier of the
input program or a character string that is received from an external device (for example,
eCAP, eAPI).
DECT Messenger Customer Engineer Manual
100 DECT Messenger Fundamentals March 2012