Customizing Line Pools
117353-B Rev. 00
9-11
For example:
serial/3/3# media-type v25bis
To set the cable type, do the following:
cable-type <
value
>
value can be: null, rs232, s422, v35, x21
Select the option that corresponds to the interface type supported by the attached
dial device.
For example:
dial/serial/3/3# cable-type rs232
Using Site Manager
To modify the line media type and cable type:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the COM connector whose
interface you want to change.
The connector name should have a D, B,
or W next to it.
The Edit Connector window opens.
2. Click on
Edit Line
. The Edit SYNC Parameters window
opens.
3. Set the following parameters:
• Line Media Type
• Cable Type
Click on
Help
or see the parameter
descriptions beginning on page A-5.
4. Click on
OK
. You return to the Edit Connector window.
5. Click on
Done
. You return to the Configuration Manager
window.
Komentarze do niniejszej Instrukcji