Configuring Dial Services
10-14
308621-14.00 Rev 00
To set the initialization string, navigate to the modem prompt and enter:
init-string
<string>
string
is an AT modem command string, which is an ASCII text string from 3 to
34 characters.
For example, to send a command to turn off the command echo, enter:
modem/3/3# init-string E0
Using Site Manager
To set the initialization string for the ARN:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the COM connector whose
configuration you want to change.
The connector name should have a D, B,
or W next to it.
The Edit Connector window opens.
2. Click on
Edit Modem
. The V.34 Modem Interface Parameters
window opens.
3. Set the
Modem Config String
parameter.
See the parameter description on
page A-15.
4. Click on
OK
. You return to the Edit Connector window.
5. Click on
Done
. You return to the Configuration Manager
window.