Troubleshooting a Data Link Layer Problem
117379-A Rev. A 5-25
If transmission and reception statistics increment equally without errors, conduct
a loopback test of the remote CSU/DSU if at least one of the following is true:
You configured the synchronous line as standard with explicit addressing.
You configured the data terminal equipment/data communications equipment
(DTE/DCE) with promiscuous mode turned on.
The remote loopback test allows data to leave the router, cross the synchronous
circuit to the remote CSU/DSU, and return to the router.
If the transmission and reception statistics increment without errors, perform the
local and remote loopback tests on the remote side.
If the local loopback test did not cause any error count to be incremented, but the
remote loopback test did, request that the carrier test the line and remote
CSU/DSU.
If the local loopback test causes the error counts to continue to increment,
complete one of the following procedures to isolate the problem:
Disconnect the cable from the port of the router reporting the errors and plug
it into another port on the router you know works correctly.
If the synchronous errors persist, verify that you properly configured the
newly tested port, test the cable, and test the local CSU/DSU.
If the errors stop, compare the newly tested port’s configuration with that of
the original port. If the port configurations are the same, try swapping the link
module with a new link module.
Connect the port of the router reporting the errors to another CSU/DSU and
monitor the line statistics.
If the errors persist, try another cable or try swapping the link module with a
new link module.